Se-Kure Controls LE PLUS Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Systèmes de contrôle d'accès de sécurité Se-Kure Controls LE PLUS. Se-Kure Controls LE PLUS Operating instructions [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 11
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation Instructions for the
ME Sr. III Alarm System
SK-210ME (Key Unit)
SK-210KME (Keypad Unit)
SK-295
AC/DC Power Supply
SKP-416K
Special Allen Key
SK-107ME
6 Port ME Splitter
SK-206ME
6 Port ME Strip Module
SK-212ME
12 Port ME Strip Module
Operation Guide
The ME Senior III Alarm Module is designed
to handle up to 12 terminals, (6 or 12 port
strips and 6 port splitter boxes in any combina-
tion), protecting up to 144 items. New micro-
processor technology enables the system to
identify the number of alarm sensors connected
to it, monitor battery level, and perform a con-
tinuous series of system-wide tests that look for
changes resulting from possible tampering.
Lighted LED Bar Graphs visually depict the
condition of batteries and AC power. When an
alarm occurs, it shows precisely which sensor
on which terminal caused the alarm.
The ME Alarm System utilizes the Se-Kure
Controls complete line of “LE” sensors.
Terminals:
Reading Time: 8 Minutes
SK-210KME
ME Sr. Keypad Alarm Module
Page 1
Install the AC/DC Adapter:
1. Plug the SK-295 AC/DC Adapter* into the
power supply jack on the back side of the alarm
module as shown in Fig. 1 at right.
Note: Always use a Se-Kure Controls (SK-295)
AC/DC Power Supply with Se-Kure alarms.
(Using a universal adapter could damage the
system and would void the warranty).
2. Plug the other end of the adapter into any
standard 110v wall outlet.
*International Users May Require a Special Adapter for 220v, (not supplied).
Fig.
1
SK-295
AC/DC Power Supply
Terminal Connection
(from ME Strip Alarm or ME Splitter Box)
Vue de la page 0
1 2 3 4 5 6 ... 10 11

Résumé du contenu

Page 1 - III Alarm System

Installation Instructions for theME Sr. III Alarm SystemSK-210ME (Key Unit)SK-210KME (Keypad Unit)SK-295AC/DC Power SupplySKP-416KSpecial Allen KeySK-

Page 2 - Battery Installation:

Installation & Operation Instructions for theSK-T6 ALARM MODULESK-1106 Port T-6 Alarm ModuleExtra KeySK-195AC/DC Power Supply(6) “AA” Alkaline Bat

Page 3 - To Splitters & Strips

Se-Kure Controls,®Inc.3714 Runge Street • Franklin Pk., IL 60131 • 1-(800) 322-2435 • (847) 288-1111 • Fax (847) 288-9999©2001 Se-Kure Controls,®Inc.

Page 4 - Keypad Operation:

Install Terminals:When the power is first applied to the (SK-210KME) Keypad Alarm System, the keypaduses the factory pre-set code: 1-2-3-4.6. To deact

Page 5

Page 3RectangularAdhesive PadSK-905Fig. 4Fig. 5Sensor Connections: – To Splitters & Strips9. Insert a sensor’s modular plug into a splitter or str

Page 6

Bar Graph Displays(Example shows a “HIT” or Tampered Sensor on the3rd Port of Terminal #6)Chasing LED Lights(Indicate that the Systemis in an Armed Mo

Page 7 - Installation:

Arm the System:With all the Terminals, (Strips & Splitters), andSensors attached:• Check to see there are no flashing LED Lights on Sensors.• Chec

Page 8 - Keypad Instructions:

Installation Instructions for theME Jr. plus 2 Alarm SystemSK-800KME SeriesSK-3690(Optional) “Where it’s At Light”SK-807MEME Jr. plus 2 (8) Port Split

Page 9

AC Power LightWill be lit when the SK-195 AC/DCPower Supply is supplying power tothe Alarm Center.Low Battery LightWill )))flash((( when batteriesshou

Page 10 - SK-T6 ALARM MODULE

3.The “Where It’s At” LED Light:All ME Jr. Splitter Boxes and Strips are equipped with a “Where It’s At” light jack, for this optional accessory. When

Page 11 - Se-Kure Controls

Se-Kure Controls,®Inc.3714 Runge Street • Franklin Park, IL 60131 • 1-(800) 322-2435 • (847) 288-1111 • Fax: (847) 288-9999Rev. 7/22/02 SCI-9759©2002

Commentaires sur ces manuels

Pas de commentaire